unix: change the mksysnum master to point to stable/11 on freebsd

Add a COMPAT10 directive to mksysnum.go to keep generating SYS_PIPE.

Updates golang/go#27619

Change-Id: Ifb54a812baf79c9426ce864bb0ef0e66b19d7f3b
Reviewed-on: https://go-review.googlesource.com/c/sys/+/182318
Run-TryBot: Tobias Klauser <tobias.klauser@gmail.com>
TryBot-Result: Gobot Gobot <gobot@golang.org>
Reviewed-by: Tobias Klauser <tobias.klauser@gmail.com>
This commit is contained in:
Yuval Pavel Zholkover
2019-06-14 16:08:38 +00:00
committed by Tobias Klauser
parent d442b75600
commit b47fdc9379
6 changed files with 252 additions and 272 deletions
+1 -1
View File
@@ -139,7 +139,7 @@ func main() {
text += format(name, num, proto)
}
case "freebsd":
if t.Match(`^([0-9]+)\s+\S+\s+(?:NO)?STD\s+({ \S+\s+(\w+).*)$`) {
if t.Match(`^([0-9]+)\s+\S+\s+(?:(?:NO)?STD|COMPAT10)\s+({ \S+\s+(\w+).*)$`) {
num, proto := t.sub[1], t.sub[2]
name := fmt.Sprintf("SYS_%s", t.sub[3])
text += format(name, num, proto)